Select Page

The loader arm drifts while holding a load, and you're trying to decide whether the pump needs replacing. Before ordering the same unit again, separate the symptoms: slow lifting can point towards inadequate pump delivery, while drift with the controls centred can come from leakage through a valve or cylinder. Changing gear pump types won't cure every hydraulic fault.

The useful question is which design will deliver the required oil flow, survive the machine's duty and remain safe to inspect and maintain. That means looking beyond the shaft and mounting flange to the inlet conditions, relief protection, isolation arrangements and access for servicing.

Gear Pump Types at a Glance

The main hydraulic gear pump designs are external gear, internal gear with a crescent, and gerotor. Reversible external gear pumps are a further variant, rather than a separate pumping principle.

External gear pumps are the most common starting point for mobile hydraulic duties because they combine straightforward construction with a durable layout. Internal gear pumps favour smoother, quieter industrial operation. Gerotors package the pumping elements tightly, making them useful where installation space is restricted.

Main gear pump types compared

TypeHow it moves oilTypical maximum pressureTypical usesMain limitation
External gearTwo meshing gears carry oil between teeth and the housingUse the selected model’s continuous and intermittent pressure ratingsMobile machinery, PTO drives, implements, loadersInternal leakage and pressure ripple become important at higher pressure
Internal gear (crescent)An outer ring gear and inner pinion rotate around a crescent separating inlet and outletUse the hydraulic or transfer-duty rating for the selected modelSmoother industrial circuits, lubrication and transfer dutiesMore components, including a crescent sealing surface that can wear
GerotorOffset inner and outer rotors form expanding and contracting chambersUse the selected rotor set’s rated working pressureCompact power packs, steering assist, small drivesSensitive to contamination and restricted by available displacement sizes
Reversible external gearA bidirectionally designed gear arrangement pumps with either shaft directionCheck the reversible rating explicitly, rather than adopting the unidirectional ratingWinches, reversing drives, bidirectional circuitsMay trade pressure capability and efficiency for bidirectional operation

There's no defensible universal pressure band for each architecture. Typical values are only orientation figures; the manufacturer's datasheet governs. Complete any numerical pressure comparison from the shortlisted supplier datasheets, including the distinction between continuous operation and permitted pressure peaks.

Use the duty to narrow the choice

A loader or PTO-driven implement usually points towards an external gear pump. Steering assistance or a small integrated power pack can bring a gerotor onto the shortlist, although compact external gear pumps may also fit.

Don't treat the table as a ranking. An internal gear pump's smoother delivery can be more valuable in a factory than the simpler construction that makes an external pump attractive on an implement.

The IndexBox UK hydraulic pump market overview groups gear, vane and other rotary positive-displacement pumps together, so broad market totals don't identify the best architecture for your machine. Shortlist the plausible types using the application, then compare actual models against operating and maintenance requirements.

How External, Internal and Gerotor Pumps Move Oil

Think of an external gear pump as a pair of revolving doors. The spaces between the teeth carry pockets of oil around the outside of the gears, not through the point where they mesh.

A gloved hand holds a drive shaft connected to internal spur gears of an industrial gear pump.

External gears carry oil around the casing

As the teeth separate at the inlet, the available space increases and oil enters. The rotating gears trap it between the tooth spaces and housing, carrying it towards the outlet. Where the teeth mesh again, the spaces close and displace the oil into the discharge passage.

The meshing teeth help separate the inlet and outlet, while close clearances around the gear faces and tooth tips limit leakage. Wear opens these paths, allowing more oil to slip internally instead of reaching the circuit.

For the service engineer, this is usually the simplest arrangement to understand and inspect after safe removal. Check the housing for scoring, the gear faces for damage and the shaft support for wear, following the manufacturer's repair limits.

Internal gears use a crescent separator

A crescent-type internal gear pump places a smaller externally toothed pinion inside a larger internally toothed ring. A stationary crescent-shaped component divides the inlet and discharge zones while oil travels through the spaces between the teeth.

The engagement geometry generally produces smoother delivery and quieter operation than a basic external spur-gear arrangement. That's useful beside an operator's workstation or where pressure ripple affects the process, but it doesn't make the pump immune to noise from poor inlet conditions.

The crescent and adjacent running surfaces are important inspection points. Damage there can compromise the separation between suction and discharge, reducing useful delivery.

Gerotors change chamber volume

A gerotor has an inner rotor with fewer teeth than its surrounding outer rotor. Their offset centres create chambers that expand on the inlet side and contract towards the outlet, without needing a separate crescent.

Compactness is the attraction, but rotor clearances and surface condition matter. Particles that score the working surfaces can undermine sealing, so a small package still needs proper filtration and clean assembly.

A healthy pump delivers consistently for its operating condition, without a new harsh whine, unusual vibration or oil escaping at the shaft. Inspect from a safe position with guards fitted, never by reaching towards a rotating coupling.

Unidirectional, Reversible and Fixed Displacement Designs

Fixed displacement describes volume per shaft revolution, not direction of rotation. A pump can be fixed displacement and either unidirectional or reversible, so those labels aren't competing categories.

Consistent terminology helps prevent purchasing mistakes. ISO 17769-1:2012 establishes terminology, symbols and units for liquid pumps and installations; for a practical comparison, record displacement in cm³/rev, flow in L/min, speed in rev/min and pressure in bar.

A technical chart explaining the operation of unidirectional, reversible, and fixed displacement gear pumps with performance graph.

Displacement isn't delivered flow

Theoretical flow is displacement multiplied by shaft speed, with the units converted appropriately. For a worked example, take a nominal 160 cm³/rev pump running at 540 rev/min:

Theoretical flow = 160 × 540 ÷ 1,000 = 86.4 L/min.

Delivered flow will be lower because some oil leaks through internal clearances. Those volumetric losses generally increase as pressure rises and oil viscosity falls. A worn pump may therefore perform acceptably without load but struggle once the circuit demands working pressure.

Pressure itself isn't a fixed output that the pump generates independently. The circuit's resistance to flow establishes operating pressure, within the limits imposed by the drive, pump and protective devices.

Rotation changes the specification

A unidirectional pump is designed for a stated shaft direction, with its porting, bearing compensation and shaft-seal arrangements configured accordingly. Never reverse it just because the shaft can physically turn backwards.

A reversible pump is designed to accommodate either shaft direction, with inlet and outlet functions exchanging as specified. Some designs sacrifice pressure capability or efficiency for that flexibility, but the actual trade-off is model-specific.

Also distinguish reversing the actuator from reversing the pump. A winch can reverse through a directional valve while its supply pump continues rotating in the same direction.

Before comparing suppliers, extract these details:

  • Displacement: Record the stated volume per revolution.
  • Maximum speed: Check the permitted speed across the intended viscosity range.
  • Maximum pressure: Separate continuous duty from intermittent limits.
  • Rotation: Confirm the direction and the viewpoint used to describe it.

If the pump shaft never reverses, start with a unidirectional model. If it does, use the explicit reversible specification.

Where Gear Pumps Work, From Tractors to Factory Power Packs

Agricultural equipment makes the appeal of external gear pumps easy to understand. A tractor implement needs a compact source of oil flow, driven by equipment already on the machine, with components that a service engineer can identify and replace without unnecessary complexity.

Consider a PTO circuit using the nominal displacement and speed in the worked example. Its theoretical delivery isn't a promise of flow at working pressure, and the installation still needs an adequate reservoir, suitable suction pipework and a correctly matched drive.

For an application-level pressure reference, MA Hydraulics' PTO pump guidance describes a pump specification with a maximum pressure of approximately 155 bar. Treat that as an example, not a universal gear-pump limit: the relief setting must respect the lowest-rated component, with appropriate allowance for pressure transients.

Agricultural and mobile duties

On a loader, pump delivery affects lifting speed, while the valve arrangement controls how the load is directed and held. An external gear pump is a practical starting point, but increasing displacement without checking the engine drive, inlet capacity and valve flow rating can create new problems.

For an implement that only runs intermittently, ask how often it operates and for how long. For mobile plant exposed to seasonal weather, ask about ambient temperature and the oil's cold-start behaviour.

Operators also need to understand the machine, not just its hydraulic components. The TP Training plant operations guide offers Australian training context for plant operation; UK users should apply the relevant UK training and machinery-safety requirements.

Materials handling and factory equipment

A materials-handling lift may combine repeated short movements with prolonged periods holding a load. The first question is where pressure peaks occur during starting, stopping or lowering, rather than whether the average operating pressure looks acceptable.

A factory power pack may run beside people throughout production. An internal gear design can be attractive where smoother delivery and noise control matter; a gerotor may suit a smaller integrated circuit if its pressure and displacement ratings fit.

  • Dirty environments: Ask how contamination enters during filling, hose changes and servicing.
  • Continuous operation: Check the heat balance across the complete duty cycle.
  • Enclosed installations: Allow space for cooling, filter changes and pump removal.

Choosing a Gear Pump Safely Under UK Pressure Rules

The HSE's pressure-systems guidance describes pressure systems containing, or likely to contain, a relevant fluid above 0.5 bar, and stresses suitable equipment, known safe operating limits and functioning protective devices. Relevant fluid is important: pressure alone doesn't decide which regulations apply.

The HSE's guidance on PSSR explains that hydraulic oil systems are generally outside the Pressure Systems Safety Regulations 2000. Don't assume a hydraulic circuit needs a written scheme of examination solely because it operates at high pressure; assess the actual equipment, fluid and stored-energy arrangements.

Selection criteria for a gear pump

CriterionQuestion to askWhy it matters
Pressure ratingDoes the pump’s permitted pressure cover circuit peaks with suitable margin?Pump, hose, seal and fitting ratings must all cover the conditions they experience
Relief protectionIs a correctly set relief or safety valve connected to protect the pump discharge?A positive-displacement pump continues displacing oil as resistance rises
Isolation and depressurisationCan the circuit be isolated and stored pressure released before work?Residual energy can cause unexpected movement or cycling
Accessibility for serviceCan the pump be inspected or replaced without dismantling adjacent equipment?Difficult access increases downtime and maintenance exposure
Contamination sensitivityHow well does the design tolerate particles and water?Gerotors and other close-clearance designs can suffer rapid wear in dirty oil
Monitoring pointsAre pressure, temperature and filter-checking points accessible?Technicians need usable measurement locations to establish reliable trends

Make safe servicing part of the design

The HSE's PUWER overview requires suitable, maintained work equipment and appropriate means of isolation. In practice, stopping the motor isn't enough: support raised loads mechanically, isolate relevant energy sources and release trapped hydraulic pressure using the machine's defined procedure.

The HSE's hydraulic-fluid safety guidance identifies high-pressure injection as a machinery hazard and addresses protective arrangements and safe pressure removal. Never use a hand to search for a leak, and treat suspected injection injury as an emergency requiring immediate medical attention.

Relief protection needs a route that remains effective whenever the pump can run. Use the pressure relief valve sizing guide when assessing valve capacity, not just its pressure adjustment.

Selection rule: Screen pumps by pressure and speed, then verify relief protection, isolation and service access before comparing purchase price.

A compact installation isn't economical if routine inspection requires working beside an unsupported load or removing unrelated equipment. Leave room for tools, capped pipe connections and a controlled removal route.

Diagnosing Noise, Flow Loss and Heat in Service

A whining or rough-running pump should send you towards the inlet checks before you condemn the gears. Restricted suction pipework, air ingress and cold, viscous oil can all prevent the pumping chambers filling properly.

Listen from a safe position and compare the sound under repeatable operating conditions. A noise that appears only at cold start suggests a different investigation from one that develops after the oil reaches working temperature.

Gear pump symptoms, causes and first checks

SymptomLikely causeFirst check
Whining or rough noiseRestricted suction line, air ingress or cold, viscous oilInlet line, filter condition and oil temperature
Flow drops under loadInternal wear or a passing relief valvePressure reading against the relief setting, followed by controlled flow testing
Foaming oilAir entering the suction sideSuction seals, oil level and return-line arrangement
Pressure spikesBlocked relief path or cold-start pressureRelief valve operation and warm-up sequence
OverheatingExcess pressure, prolonged relief operation or poor delivery efficiencyLoad cycle, relief setting and cooling performance
Leak at shaftWorn shaft seal or excessive pressure at the sealSeal condition and case-drain pressure where a drain is fitted

These are starting points, not final diagnoses. For example, poor actuator speed can result from pump wear, a relief valve passing oil, or leakage elsewhere in the circuit. The hydraulic pump failure causes guide provides further context for separating component faults from installation problems.

Choose monitoring that leads to action

ChannelLife's report on UK manufacturing maintenance says predictive-maintenance adoption rose from 9% to 22%, while reactive maintenance fell from 42% to 26%. That's a shift towards planned intervention, not evidence that every pump needs a digital retrofit.

For a smaller plant, start with repeatable pressure and temperature checks, filter-condition monitoring, contamination control and a trend log. Record the load, shaft speed and oil condition alongside measurements so technicians aren't comparing unrelated operating states.

High-utilisation equipment may justify continuous condition monitoring where stoppages are expensive. Sensors can help reveal developing wear, inlet problems or extended relief-valve operation, but only when someone has defined alarm limits and the response to them.

Set the monitoring level by the cost and consequence of a stoppage, not by the pump's purchase price.

Avoid alarms based on a single unexplained reading. Confirm the operating state, check the instrument and investigate the trend before authorising replacement.

Match the Gear Pump Type to Your Machine

The right choice starts with the machine's duty, not a preference for a particular architecture. Use the application to build a shortlist, then confirm the exact model against the hydraulic circuit and physical installation.

  • PTO or engine-driven mobile machinery: Start with an external unidirectional pump where the shaft runs in a single direction.
  • A shaft that must reverse: Select a reversible pump and check its own pressure, speed and porting requirements.
  • Smoother industrial or lubrication duty: Consider an internal gear pump, with attention to fluid compatibility and viscosity.
  • Compact power packs or steering assistance: Consider a gerotor where the available displacement and pressure ratings suit the duty.

A farmer using a metal wrench to repair the PTO shaft mechanism on a tractor attachment.

Complete the ordering checks

Confirm the circuit's peak pressure and relief setting, establish how the pump will be isolated and removed, and decide what monitoring the machine needs. Then verify the shaft, mounting flange, port threads, coupling and rotation convention against the existing assembly.

Check the inlet arrangement too. A hydraulic suction strainer must be selected with inlet restriction and cold-oil behaviour in mind; finer filtration isn't automatically better on the suction side.

Our range includes Vivoil Group 0, Group 1, Group 2 and Group 3 pumps, alongside 10T & 11T spline gear pumps and P18 parallel shaft gear pumps. We also offer Vivoil hydraulic gear motors and geared type flow dividers, allowing the component discussion to reflect the wider circuit rather than the pump alone.

Prepare pressure in bar, speed in rev/min, displacement in cm³/rev, rotation direction and a description of the machine's duty. Add photographs of the nameplate, shaft, flange and ports where identification is uncertain, plus details of the fault if you're replacing a failed unit.


MA Hydraulics Ltd offers hydraulic gear pumps and component-selection support for mobile and industrial machinery, helping you match the design to the drive, circuit and service requirements. Visit MA Hydraulics Ltd, phone 01724 279508 today, or send us a message with your operating figures so our team can recommend a suitable gear pump type.

author avatar
Gemma Hydraulics PA to the Directors
Gemma works closely with the directors and technical team at MA Hydraulics, helping communicate the company’s practical knowledge of hydraulic components and systems. She produces and coordinates content covering hydraulic products, maintenance, troubleshooting and applications, drawing on the experience of the wider MA Hydraulics team.